Categories

Mean Well Arcade Machine/JAMMA Power Supply - Switching - +12V, +5V, -5V

(No reviews yet) Write a Review
£35.99 - £39.89 (Inc. VAT)
£29.99 - £33.24 (Ex. VAT)
Condition:
New
Shipping:
Calculated at Checkout

Description

This Mean Well power supply is suitable for various arcade machine/JAMMA projects. Featuring +12v, +5v AND -5v, this power supply is very reliable and manufactured by one of the most trusted names for power supplies - Mean Well.
CE certified and ISO-9001 certificated. This Mean Well power supply can withstand 300v AC surge input for 5 seconds and features short circuit, overload and over voltage protection. Don't settle for cheaper unreliable power supplies - give your arcade project the reliability and performance it deserves with one of these reliable, quality power supplies. 

Product Features:
* Protections: Short circuit / Overload / Over voltage
* Cooling by free air convection.
* LED indicator for power on
* 100% full load burn-in test
* All using 105°C long life electrolytic capacitors
* Withstand 300VAC surge input for 5 second
* High operating temperature up to 70°C
* Withstand 5G vibration test
* High efficiency, long life and high reliability
* 3 years warranty

Specification:

Model RT-125A
Output Output Number CH1 CH2 CH3
DC Voltage 5V 12V -5V
Rated Current 12A 5.5A 1A
Current Range
Note 3
0 ~ 12A 0 ~ 6A 0 ~ 1A
Rated Power
Note 6
131W
Ripple & Noise (max)
Note 2
80mVp-p 120mVp-p 80mVp-p
Voltage Adj. Range CH1: 4.75 ~ 5.5V
Voltage Tolerance
Note 3
±2.0% +9,-5% +6,-10%
Line Regulation ±0.5% ±1.0% ±1.0%
Load Regulation ±1.0% ±3.0% ±6.0%
Setup, Rise Time 500ms, 20ms/230VAC
1200ms, 30ms/115VAC at full load
Hold Up Time (Typ.) 25ms/230VAC - 30ms/115VAC at full load
Input Voltage Range 88 ~ 132VAC / 176 ~ 264VAC selected by switch 248 ~ 373VDC
(Withstand 300VAC surge for 5 sec. Without damage)
Frequency Range 47 - 63Hz
Efficiency (Typ.) 77%
AC Current (Typ.)  3A/115VAC - 2A/230VAC
Inrush Current (Typ.)  Cold Start 50A/230VAC
Leakage Current  <2mA / 240VAC
Protection Overload 110 ~ 150% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
Over Voltage CH1: 5.75 ~ 6.75V
Protection type : Hiccup mode, recovers automatically after fault condition is removed
Environment Working Temp -25 ~ +70 (Refer to "Derating Curve")
Working Humidity 20 ~ 90% RH non-condensing
Storage Temp., Humidity -40 ~ +85 , 10 ~ 95% RH
Temp. Coefficient ±℃ ℃ 0.03%/ (0 ~ 50 )on +5V output
Vibration 10 ~ 500Hz, 5G 10min./1cycle, period for 60min. each along X, Y, Z axes
Safety & EMC
Note 7
Safety Standards UL62368-1, TUV EN62368-1 approved
Withstand Voltage I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
Isolation Resistance I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
EMC Emission Compliance to EN55032 (CISPR32) Class B, EN61000-3-2,-3, BS EN/ BS EN/ EAC TP TC 020
EMC Immunity Compliance to EN61000-4-2,3,4,5,6,8,11, EN61000-6-2 (EN50082-2), heavy industry level, criteria A, BS EN/ BS EN/ BS EN/ EAC TP TC 020
Others MTBF 209.3Khrs min.
MIL-HDBK-217F (25 )
Dimension 199*98*38mm (L*W*H)
Packing 0.7Kg; 20pcs/14Kg/0.85CUFT

Notes:
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°C of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance: includes set up tolerance, line regulation and load regulation. (In order to meet tolerance, it is recommended that CH1 load > 15% rated current for A, B, D type and CH1 load> 20% rated current for C type.)
4. Line regulation is measured from low line to high line at rated load.
5. Load regulation is measured from 20% to 100% rated load, and other output at 60% rated load.
6. Each output can work within current range. But total output power can't exceed rated output power.
7. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to "EMI testing of component power supplies." (as available on http://www.meanwell.com)
8. Length of set up time is measured at cold first start. Turning ON/OFF the power supply very quickly may lead to increase of the set up time.
9. The ambient temperature derating of 3.5°C/1000m with fanless models and of 5°C/1000m with fan models for operating altitude higher than 2000m(6500ft).
* Product Liability Disclaimer: For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx