Product Description
Product Code: RS-35-12
35W Single Output Switching Power Supply.
This power supply is ideal for illuminating arcade buttons
Illuminated Arcade Buttons
To connect to the black JAMMA power supply, simply cut off the connector and strip back the plastic sleeve to reveal the wires.
Brown wire = Live
Blue wire = Neutral
Green wire = Earth
Power Cable:
We sell various power cables that can be used with this power supply here: Wires & Cables
Features:
Universal AC input / Full range
Protections: Short circuit / Over load / Over voltage
Cooling by free air convection
LED indicator for power on
100% full load burn-in test
All using 105°C long life electrolytic capacitors
Withstand 300VAC surge input for 5 second
High operating temperature up to 70°C
Withstand 5G vibration test
High efficiency, long life and high reliability
No load power consumption<0.5W
Specifications:
MODEL | RS-35-12 | |
OUTPUT | DC VOLTAGE | 12V |
RATED CURRENT | 3A | |
CURRENT RANGE | 0 ~ 3A | |
RATED POWER | 36W | |
RIPPLE & NOISE (max.) Note.2 | 120mVp-p | |
VOLTAGE ADJ. RANGE | 10.8 ~ 13.2V | |
VOLTAGE TOLERANCE Note.3 | ± 1.0% | |
LINE REGULATION Note.4 | ± 0.5% | |
LOAD REGULATION Note.5 | ± 0.5% | |
SETUP, RISE TIME | 500ms, 50ms/230VAC 1200ms, 50ms/115VAC at full load | |
HOLD UP TIME (Typ.) | 80ms/230VAC 15ms/115VAC at full load | |
INPUT | VOLTAGE RANGE | 88 ~ 264VAC 125 ~ 373VDC (Withstand 300VAC surge for 5sec. Without damage) |
FREQUENCY RANGE | 47 ~ 63Hz | |
EFFICIENCY(Typ.) | 84.5% | |
AC CURRENT (Typ.) | 0.8A/115VAC 0.55A/230VAC | |
INRUSH CURRENT (Typ.) | COLD START 36A/230VAC | |
LEAKAGE CURRENT | <2mA / 240VAC | |
PROTECTION | OVERLOAD | 110 ~ 150% rated output power |
Protection type : Hiccup mode, recovers automatically after fault condition is removed | ||
OVER VOLTAGE | 13.8 ~ 16.2V | |
Protection type : Hiccup mode, recovers automatically after fault condition is removed | ||
ENVIRONMENT | WORKING TEMP. | -25 ~ +70°C (Refer to "Derating Curve") |
WORKING HUMIDITY | 20 ~ 90% RH non-condensing | |
STORAGE TEMP., HUMIDITY | -40 ~ +85°C , 10 ~ 95% RH | |
TEMP. COEFFICIENT | ±0.03%/°C (0 ~ 50°C) | |
VIBRATION | 10 ~ 500Hz, 5G 10min./1cycle, period for 60min. each along X, Y, Z axes | |
SAFETY & EMC (Note 6) |
SAFETY STANDARDS | UL60950-1, TUV EN60950-1 approved |
WITHSTAND VOLTAGE | I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC | |
ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25°C / 70% RH | |
EMC EMISSION | Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3 | |
EMC IMMUNITY | Compliance to EN61000-4-2,3,4,5,6,8,11, EN61000-6-2 (EN50082-2), heavy industry level, criteria A | |
OTHERS | MTBF | 249Khrs min. MIL-HDBK-217F (25°C) |
DIMENSION | 99*82*36mm (L*W*H) | |
PACKING | 0.3Kg; 45pcs/14Kg/0.83CUFT | |
NOTE | 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°C of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. Line regulation is measured from low line to high line at rated load. 5. Load regulation is measured from 0% to 100% rated load. 6. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” |